Mini Split — North America Inverter SEER2 18
Inverter mini-split system for the North American market, rated up to SEER2 18.
Specifications
Detailed dimensional and performance data for this family is being finalised. Ask us for the current submittal sheet.
Overview
A mini split is a ductless split system: an indoor fan coil mounted in the room, an outdoor unit outside, and a line set between them. This family is the North American inverter mini split published up to SEER2 18, aimed at cooling a space where ductwork does not exist or cannot reasonably be extended.
In a project it is normally room-level or small-zone: an addition, a converted space, a site office, or the one room a ducted system never reaches. Selection is straightforward in principle but depends on model-level data we do not yet publish at family level — capacity, electrical supply, line-set limits, control interface and refrigerant are all confirmed per model.
Where it is used
- Room-level cooling where ductwork is unavailable or impractical
- Additions, converted basements and attics, and sunrooms
- Small commercial and tenant spaces, site offices and equipment rooms
- One problem room an existing ducted system cannot reach
Selection & installation notes
- 01
Size from a room load calculation, not a rule of thumb. The published rating is a ceiling for the family, not a capacity table, so take capacity from the model data.
- 02
Confirm the refrigerant and factory charge per model; the family data lists no refrigerant.
- 03
Confirm line-set length and elevation limits, and whether the line set is supplied or ordered separately — neither is published at family level.
- 04
Check the installation envelope: wall area and clearances for the indoor head, outdoor clearances, and a condensate route, gravity or pumped as the model requires.
- 05
Confirm the electrical supply and circuit protection per model; electrical data is not published at family level.
Common questions
What does SEER2 18 mean for this family?
SEER2 is the seasonal efficiency rating used for air-conditioning equipment in North America, and this family is published up to SEER2 18. Ratings are determined per model, so request the figure and its test conditions.
Is it a heat pump or cooling only?
Our published family data does not state this. Confirm the operating mode, heating capacity and applicable ambient range for the model you are quoting.
Does the system carry Canadian approval marks?
We do not publish approval marks or claims in product copy. Ask your account contact for the factory documentation for the exact model you are quoting, and check the model against it.
Can one outdoor unit serve several rooms?
Multi-zone configurations are not in the published data for this family. Send the room count and each load and we will confirm what the factory can offer.
Related products
A-Coil & Cased Evaporator Coils
Cased evaporator coils matched to our side-discharge outdoor units, in three coil sizes. Custom and OEM coil configurations available.
Side-Discharge Outdoor Units
SEER2 18 inverter side-discharge condensing units, 1.5–5 ton, designed to pair with A-Coils, AHUs and field replacement of existing condensers.
Top-Discharge Outdoor Units
Top-discharge condensing units, 2–5 ton, with GMCC compressors and DC fan motors.