Wall Cap Vents — Intake & Exhaust
Through-wall intake and exhaust caps in 4", 5" and 6" duct sizes, with a drip edge, a fixed bird screen and a removable hood.
Specifications
| Parameter | Value |
|---|---|
| Nominal duct size | 4" · 5" · 6" |
| Collar inside diameter | 101.9 mm (4") · 127.5 mm (5") · 152.9 mm (6") |
| Flange, W × H | 246 × 210 mm (4" and 5") · 302 × 251.2 mm (6") |
| Hood opening, W × H | 170 × 153.3 mm (4" and 5") · 226 × 189 mm (6") |
| Projection from wall face | 138.4 mm (4" and 5") · 154 mm (6") |
| Material | UV-stabilised polymer resin |
| Colour | White as standard; black optional |
| Screen and hood | Fixed bird screen (not removable); removable hood |
| Damper | Factory-fitted; remove for intake applications |
Values as published in the 2026 product catalogue. Ask us for the model-level submittal sheet before specifying.
Features
- ✓One range for intake and exhaust applications
- ✓UV-stabilised polymer resin
- ✓Drip edge carries water away from the wall
- ✓Removable hood for cleaning or replacement
- ✓Fixed bird screen — the screen is not removable
- ✓Factory-fitted damper, removed for intake applications
- ✓Flange with fixing holes for direct fastening to the wall
- ✓4", 5" and 6" sizes; white as standard, black optional
Overview
A wall cap is where a duct run leaves the building: a flanged base fixes to the exterior wall, a hood covers the opening, and a bird screen sits behind it. This range covers 4", 5" and 6" ducts in one moulded body of UV-stabilised polymer resin, with a drip edge under the hood. Because the hood is removable and the base is a single moulded part, there is no joint at the wall for water to work into and nothing to repaint.
The same cap serves both sides of the air path. On exhaust — a bathroom or kitchen extract fan, a range hood — the damper stays in and the screen keeps birds out. On intake — furnace combustion air or fresh-air make-up — the damper is taken out so air passes freely. That is a decision to settle before the wall is opened, because the damper is far easier to remove with the cap on the bench than after the flange is screwed to the sheathing.
Sizing follows the duct. The collar inside diameter is 101.9 mm for 4", 127.5 mm for 5" and 152.9 mm for 6", and the body grows with it: the 6" flange is 302 × 251.2 mm against 246 × 210 mm on the smaller two. Projection from the wall face is 138.4 mm on the 4" and 5" bodies and 154 mm on the 6", which is the number to check against eaves, downpipes and anything the cap might discharge onto.
Where it is used
- Terminating a bathroom or kitchen exhaust fan through an exterior wall
- Range hood and stove vent through-wall termination
- Combustion-air and fresh-air intake for furnaces and make-up air
- Supply or exhaust terminal on a ducted ventilation run in a house or small commercial building
- Replacing a damaged or missing wall cap on an existing duct
Selection & installation notes
- 01
Size to the duct, not to the hole in the wall. The collar takes 4", 5" and 6" duct at 101.9, 127.5 and 152.9 mm inside; measure the duct first, then cut the opening to suit it.
- 02
Decide intake or exhaust before installation. The intake side needs the damper removed, and the flange of the models we build is marked for it: "FOR AIR INTAKE APPLICATION — REMOVE DAMPER".
- 03
Check the flange and the projection together: 246 × 210 mm and 138.4 mm on the 4" and 5" bodies, 302 × 251.2 mm and 154 mm on the 6". The flange has to sit flat on the cladding, and the projection has to clear eaves, downpipes and walkways.
- 04
Fix through the flange holes and keep the "TOP" mark up, fastening the top and two side edges. Sealant goes on the same three edges; the bottom edge stays open so water behind the flange can drain away. The sealing diagram in the reference images shows the four edges.
- 05
Tell us if the run is a clothes dryer vent. The screen in this range is fixed, so lint loading is a question for the factory to confirm rather than something to assume.
Common questions
Can one cap be used for both intake and exhaust?
Yes — that is what the damper is for. It stays in the airflow on exhaust and is removed on intake, so make that choice before the cap goes on the wall rather than after.
Is the bird screen removable?
No. The hood comes off for cleaning or replacement, but the screen itself is fixed in this range. If the application needs a different screen arrangement, tell us what it is and the factory will confirm what can be supplied.
What sizes are available, and how big is the wall opening?
Collars take 4", 5" and 6" duct, with inside diameters of 101.9, 127.5 and 152.9 mm. The flange that must sit flat on the wall is 246 × 210 mm on the 4" and 5" versions and 302 × 251.2 mm on the 6".
What colour is it supplied in?
White as standard, with black as an option. If the wall has to match a specific colour, tell us at quotation stage and the factory will confirm what can be supplied.
How is it sealed to the wall?
Sealant runs along the top edge and both side edges of the flange. The bottom edge is left unsealed so any water that gets behind the flange can escape, and the fixing holes on the bottom edge are left open for the same reason.
Read more on this topic
Related products
ERV / HRV — AspireVent Series
Heat and energy recovery ventilators, 100 / 150 CFM, side or top port, with ECM motors and a washable recovery core.
Motorized Dampers — MUD Series
Round motorized dampers for balancing fresh air against exhaust, with a silent 24 VAC hysteresis motor and spring return to closed.
Duct Fans — EC Inline Series
Inline duct fans in AC plastic, metal, EC super-silent and EC mix versions, in straight-through and housed configurations.
